Cooling Load Calculation Rts Program

    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Self Extracting File Format
    • 👥
    • Immediate download
    • $39.00

Cooling load and the methodology of calculation, an user can start running the program and perform the cooling load calculation for a model house. The selected model house is taken from an example in the ASHRAE Handbook 8. Load Calculation Program For the present program, the load calculation is based on the CLTD/SCL/CLF method. Mar 27, 2017 Uses ASHRAE commercial load calculation methods using Right-Draw or the. Calculations), and supports both CLTD and RTS load calculation methods. This program uses the 24-hour by 12 month ASHRAE Handbook of Fundamentals methods to compute light, medium or heavy heating and cooling loads for an.

See full list on carrier.com

Customers Who Bought This Also Bought

Rts
  • Elite Software--Chvac - Commercial HVAC Loads *50 zone ca...
    Priced From $599.00

  • Elite Software--Chvac - Commercial HVAC Loads *Unlimited ...
    Priced From $1,499.00

  • Skopje -- Coldroom: Calculation of Refrigeration Load for...
    Priced From $250.00

  • ASHRAE Library of Humid Air Psychrometric and Transport P...
    Priced From $159.00

Cooling Load Calculation Rts Program

About This Item

Full Description

Apr 13, 2015 The general procedure for calculating cooling load for each load component (lights, people, walls, roofs, windows, appliances, etc.) with RTS (ASHRAE) is as follows: Calculate 24 h profile of component heat gains for design day (for conduction, first account for conduction time delay by applying conduction time series). Split heat gains into radiant and convective parts. Apply appropriate. Apply RTS to Radiant Gains HOURLY COOLING LOAD. With ASHRAE Load Calculation Principles Book Software that comes. For Design Cooling Load Calculations.

[Note: this version uses I-P units only]The 2017 Radiant Time Series (RTS) Method Load Calculation Spreadsheets (in I-P units) are intended as an educational tool both for the student and for the experienced engineer wishing to explore the RTS method. They have been updated for use in the examples found in Chapter 18, Nonresidential Cooling and Heating Load Calculations, of the 2017 ASHRAE Handbook--Fundamentals.These spreadsheets allow the user to perform RTS cooling load calculations for lights, people, equipment, walls/roofs, and fenestration components. Calculate component loads for design day weather profiles for any month. Updated weather data for stations in the United States, Canada, and elsewhere around the world from the 2017 Fundamentals volume are included for ease of user selection. Solar equations in the spreadsheets are applicable to the southern hemisphere, as well.Calculate cooling and heating loads for individual rooms or block load zones. Use the 12-month cooling calculations to determine the month and time of peak cooling load for each room or block load zone. Room/zone worksheets can be copied and modified within the spreadsheet to analyze as many rooms or zones as desired; the number of rooms/zones is limited only by the available computer memory.System Requirements: WinZip and Microsoft Excel. File size is 25 MB, so we recommend a broadband internet connection when attempting to download. Zip file includes 2 files totaling 99 MB.

Cooling Load Calculation Rts Programming

Citation: ASHRAE Radiant Time Series (RTS) Method Load Calculation Spreadsheets, 2017

Browse related products from ASHRAE

  • ASHRAE >Software/CDs/DVDs >Software

[Note: this version uses I-P units only]The 2017 Radiant Time Series (RTS) Method Load Calculation Spreadsheets (in I-P units) are intended as an educational tool both for the student and for the experienced engineer wishing to explore the RTS method. They have been updated for use in the examples found in Chapter 18, Nonresidential Cooling and Heating Load Calculations, of the 2017 ASHRAE Handbook--Fundamentals.These spreadsheets allow the user to perform RTS cooling load calculations for lights, people, equipment, walls/roofs, and fenestration components. Calculate component loads for design day weather profiles for any month. Updated weather data for stations in the United States, Canada, and elsewhere around the world from the 2017 Fundamentals volume are included for ease of user selection. Solar equations in the spreadsheets are applicable to the southern hemisphere, as well.Calculate cooling and heating loads for individual rooms or block load zones. Use the 12-month cooling calculations to determine the month and time of peak cooling load for each room or block load zone. Room/zone worksheets can be copied and modified within the spreadsheet to analyze as many rooms or zones as desired; the number of rooms/zones is limited only by the available computer memory.System Requirements: WinZip and Microsoft Excel. File size is 25 MB, so we recommend a broadband internet connection when attempting to download. Zip file includes 2 files totaling 99 MB.

Cooling load calculation rts program 1

Cooling Load Calculation Rts Program 2

Cooling load calculation rts programming

Cooling Load Calculation Rts Programs

Citation: ASHRAE Radiant Time Series (RTS) Method Load Calculation Spreadsheets, 2017